WANSHIELD®62238 Solvent-Free Epoxy Self-Leveling Topcoat for Floor Coating
WANSHIELD®62238 is a high-performance, two-component, solvent-free epoxy self-leveling floor coating. Component A consists of epoxy resin, eco-friendly additives, and pigments, while Component B is a yellowing-resistant amine curing agent. The coating delivers an exceptionally smooth, glossy, and mirror-like finish with outstanding resistance to chemicals (acids, alkalis, salts, oils), abrasion, compression, and impact. Ideal for environments demanding superior cleanliness, aesthetics, and hygiene.
Product Overview
WANSHIELD®62238 is a high-performance, two-component, solvent-free epoxy self-leveling floor coating. Component A consists of epoxy resin, eco-friendly additives, and pigments, while Component B is a yellowing-resistant amine curing agent. The coating delivers an exceptionally smooth, glossy, and mirror-like finish with outstanding resistance to chemicals (acids, alkalis, salts, oils), abrasion, compression, and impact. Ideal for environments demanding superior cleanliness, aesthetics, and hygiene.
Key Features
Exceptional Self-Leveling: Forms a flawlessly smooth, high-gloss surface with excellent decorative appeal.
Superior Durability: High hardness (≥3H), exceptional wear/compression resistance, and impact strength to withstand heavy loads without scratching.
Chemical Resistance: Resists corrosion from oils, acids, alkalis, and salts; dustproof, moisture-resistant, and easy to clean.
Hygienic & Eco-Friendly: Non-toxic, pollution-free, and compliant with green standards for sterile environments.
Applications
Designed for high-traffic indoor spaces requiring cleanliness, chemical resistance, and mechanical durability, including:
Parking garages
Offices & retail spaces
Electronics/Pharmaceutical factories
Hospitals & laboratories
Food processing plants
Physical & Chemical Properties
Property | Specification | Test Standard |
---|---|---|
Condition in container | Homogeneous, no lumps after mixing | Visual inspection |
Film appearance | Smooth, glossy | Visual inspection |
Surface drying time (h) | ≤8 | GB/T 22374-2018 |
Full curing time (h) | ≤48 | GB/T 22374-2018 |
Initial fluidity (mm) | ≥140 | GB/T 22374-2018 |
Pencil hardness (H) | ≥3H | GB/T 6739-2006 |
Abrasion resistance (750g/500r, g) | ≤0.03 | GB/T 22374-2018 |
Tensile bond strength (MPa) | ≥2.0 (standard) / ≥2.0 (post-immersion) | GB/T 16777-2008 |
Impact resistance (500g/1000g steel ball) | No cracks/delamination | GB/T 22374-2018 |
Slip resistance (dry) | ≥0.5 | GB/T 22374-2018 |
Chemical resistance* | No blistering/delamination; slight discoloration allowed | GB/T 22374-2018 |
*Includes water (168h), oil (120# solvent, 72h), alkali (20% NaOH, 72h), acid (10% H₂SO₄, 48h).
Note: Data are typical values; actual performance may vary with conditions. Specifications are non-binding.
Construction Requirements
- Concrete strength ≥C25; the flatness should meet the requirement of a 2m alignment ruler with an error within 3mm.
- 28-day curing period required before application to achieve the best results.
- Ambient temperature: 5–35°C (avoid application below 5°C). as it may affect the project quality and the strength of the cured paint film.
- Substrate moisture ≤5%; ambient humidity ≤80%. Otherwise, problems such as blistering may occur, affecting the appearance.
- Ensure dust-free and ventilated environment (avoid strong airflow).
2. Surface Treatment:
- Grind the substrate to remove contaminants, loose layers, and create a rough surface for enhanced adhesion.
3. Primer Application:
Use WANSHIELD®62201 Solvent-Free Epoxy Primer or WANSHIELD®62305 Universal Epoxy Primer.
Apply via trowel or roller (0.15–0.25 kg/m²).
- Ensure no missed coating areas and avoid over – coating. If necessary, apply a second coat of primer or repair the missed coating areas.
4. Intermediate Layers:
- Mortar: Mix WANSHIELD®62208 (A:B) with 80–120 mesh quartz sand; trowel-apply.
- Putty: Mix WANSHIELD®62208 (A:B) with quartz powder; fill voids and level.
5. Topcoat Application:
Mix WANSHIELD®62238 (A:B=5:1) thoroughly; pour and spread with notched trowel.
Use spiked roller to eliminate bubbles and enhance leveling.
Construction Parameters
Mixing ratio (by weight): A:B = 5:1. use a high – speed mixer to stir thoroughly.
Pot life (25°C): 1.5 hours after mixing (1 hour after pouring). The higher the temperature, the shorter the pot life. Construction is generally not recommended when the ambient temperature during construction is higher than 35°C.
Diluent: Not allowed.
Recoat interval: The next construction process can be carried out only after confirming that the coating is completely dry. Usually, 24 hours under standard conditions (25°C, 60% humidity).
Note: Drying time varies with temperature, humidity, film thickness, and ventilation. Higher temperatures shorten drying time.
Before formal project construction, the buyer must conduct tests in an environment consistent with the construction conditions to ensure the reliability of the coating system for the specific project. Formal construction is regarded as the buyer’s recognition of the product’s performance inspection. If the above operations are not followed, all responsibilities shall be borne by the buyer.
Packaging & Storage
Packaging:
- Component A: 20kg iron drum
- Component B: 5kg iron drum
Storage & Transport:
- Store in a dry, ventilated area at 5–35°C. Avoid heat and open flames.
- Shelf life: 12 months in original packaging.
Safety Precautions
Under normal construction conditions, the dried coating is non – toxic. Please use it with confidence. For detailed information on toxicity, safety, and first aid, please refer to the Material Safety Data Sheet (MSDS) of this product.
Skin: Soap/water → seek medical help if irritation persists.
Eyes: 15-min flush → immediate ophthalmologist visit.
Fire Rating:
This product is not classified as a flammable liquid, explosive, oxidizer, corrosive, toxicant, or radioactive hazardous material during storage and transportation, and is not a hazardous product.
Fire: Use CO₂, foam, or dry chemical extinguishers.
- In the absence of other fire-fighting agents, a large amount of fog-like water can also be used for spraying. After the fire is extinguished, the spilled materials should be cleaned up (refer to the leakage and spillage treatment section).
Leakage and Spillage Treatment
Disclaimer
Contact:
Weight | 20 kg |
---|